Power Connection

OM2200 and some newer OM1200 have dual power inlets with auto failover built in. These power supplies each accept AC input voltage between 100 and 240 VAC with a frequency of 50 or 60 Hz. The OM2224-24E-10G-L draws a maximum of 48W, while non-24E are less than 30W.

Two IEC AC power sockets are located on the power side of the metal case, and these IEC power inlets use conventional IEC AC power cords.

Note: Country specific IEC power cords are not included with OM2200s. OM1200s are shipped with a 12VDC to universal AC (multi-country clips) wall adapter.

 

See also "Dual AC Supply" on page 1 and "SNMP Alerts Power" on page 1.

 

Operations Manager platform (OM1200) Environmental and Power
Power Draw < 25 Watts 
Operating conditions Temperature 0~50C, Rel Humidity 5~90% 
Cooling Passive 
Environmental Sensors Smart Controller with multi-zone temperature sensors.
Auto-shutdown/re-boot on severe thermal events
Power Draw Sensors Active multi-zone power draw monitoring  
Operations Manager platform (OM2200) Environmental and Power
Power Supply Dual AC or dual DC
Power Draw 48 Watts for -24E, others <30W 
Operating conditions Temperature 0~50C, Rel Humidity 5~90% 
Cooling Passive 
Environmental Sensors Smart Controller with multi-zone temperature sensors
Supervisory environmental controller with safety power down.
Power Draw Sensors Active multi-zone power draw monitoring